Potential Fire Protection Failures – ASSE Philadelphia Chapter – April 16, 2015

April 7, 2015
Why did this sprinkler head fail to operate in a fire?

Why did this sprinkler head fail to operate in a fire?

I will be presenting, “Potential Fire Protection Failures” at the Philadelphia Chapter of American Society of Safety Engineers’ luncheon meeting on April 16, 2015 at the Parx Casino East (Philadelphia Park Racetrack Building), 2999 Street Road, Bensalem, PA.

The pictured sprinkler head was in an actual fire. Unfortunately, it failed to operate. Why did this sprinkler head fail? What could have been done differently? How could an effective Inspection, Testing, and Maintenance program have prevented this failure?

Fire protection systems have a stellar performance record. Fire sprinklers are effective in 97% of fires in which they operate. What causes failure in the other 3%? See some of the factors which can compromise fire protection systems. The main focus of the topic is to show various parts of a fire protection system and explain why and how they may impact the proper operation of the system. The issues identified in the presentation are typically found in many industries and can be applied to the self inspection program at any facility. The talk will include examples of fire protection items which may be compromised. These items could be detected and identified by a well organized fire protection self inspection program.

On April 16 I will describe the events leading up to the fire this sprinkler head was to have controlled, why it the sprinkler head failed to operate, and the aftermath of the fire. I think you will be interested in what happened.

Additional details may be found at phila.asse.org.

I hope to see you there.


Fire Sprinkler Systems: Ensuring Reliability Through Inspection, Testing, & Maintenance

August 20, 2014

PLEASE JOIN ME AT THIS INFORMATIVE WEBINAR

OSH Supercast

A webinar presentation with Occupational Health & Safety

Your facilities have fire protection and sprinkler equipment installed, but are you sure that they are providing reliable and adequate protection at this very moment? Have the sprinkler systems installed in your facilities lulled you into a false sense of security? Are you doing what is needed to properly inspect, test, and maintain your water based fire protection systems? Are your sprinkler systems ready for response to fire? Are your fire pumps exercised and flow tested as required? Are trip test and internal inspection frequencies of your equipment adequate? Are your records reflecting the service they represent? Do you have hidden impairments in your fire systems?

Please join Walt on October 2, 2014 at 11:00am ET – 10:00am CT – 8:00am PT when he will review the requirements of NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems. Knowing the minimum requirements will help enable you to verify and evaluate the service being performed on your water based fire protection systems.

DATE: October 2, 2014

TIME 11:00AM ET – 10:00AM CT – 8:00AM PT

Register here or go to:

http://ohsonline.com/webcasts/2014/08/fire-sprinkler-systems.aspx?admgarea=Webinar&tc=page0


Watch videos of Dry Christmas Trees on Fire!

December 17, 2010

Trees used indoors for the holidays account for approximately 400 fires annually, resulting in 10 deaths, 80 injuries and more than $15 million in property damage. These videos demonstrate how quickly the fire can develop when a DRY tree is exposed to an open flame. These videos are developed by National Institute of Standards and Technology, and are made available in the public domain.

See the videos at: